Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
Add more filters










Publication year range
1.
Acta Ortop Bras ; 31(spe2): e262186, 2023.
Article in English | MEDLINE | ID: mdl-37323148

ABSTRACT

Objective: Compare the results of medial unicompartmental knee arthroplasty (UKA) using a mobile platform and total knee arthroplasty (TKA) in patients with isolated medial osteoarthritis. Methods: Retrospectivecross-sectional study. Preoperative radiographs of 602 patientswho underwent knee arthroplastybetween February 2017 and February 2020 were evaluated. Isolated medial osteoarthritis was found in 125 patients. Of these, 57 underwent UKA and 68 TKA. With chart analysis and telephone interviews, we compared patients' clinical outcomes and degree of satisfaction. The statistical analysis used a confidence level of 5%. Results: The group of UKA patients obtained 65.8% of favorable results against 79.1% of those undergoing TKA in the function questionnaire (p<0.0001). The complication rate was statistically similar between the groups(p>0.5). Most patients were satisfied or very satisfied in both groups (88.6% of UKA and 91.2% of TKA) (p>0.999). Conclusion: Patients submitted to UKA or TKA have presented the same degree of satisfaction and rate of postoperative complications when comparing patients with isolated medial osteoarthritis. UKA patients had less favorable results onthe clinical functional questionnaire than patients undergoing total arthroplasty. Level Of Evidence III;Retrospective Study.


Objetivo: Comparar os resultados da artroplastia unicompartimental do joelho (UKA) medial com plataforma móvel e artroplastia total do joelho (TKA) em pacientes com osteoartrose medial isolada. Métodos: Estudo transversal retrospectivo. Foram avaliadas radiografias pré-operatórias de 602 pacientes submetidos à artroplastia de joelho entre fevereiro de 2017 e fevereiro de 2020. A osteoartrose medial isolada foi encontrada em 125 pacientes, destes em 57 haviam sido submetidos a UKA e 68 TKA. Com análise de prontuários e entrevistas telefônicas comparamos os resultados clínicos e o grau de satisfação dos pacientes. A análise estatística utilizou nível de confiança de 5%. Resultados: O grupo de pacientes com UKA obteve 65,8% de resultados favoráveis contra 79,1% daqueles submetidos à TKA no questionário de função (p<0,0001). A taxa de complicações foi estatisticamente semelhante entre os grupos (p>0,5). A maioria dos pacientes estava satisfeita ou muito satisfeita em ambos os grupos (88,6% de UKA e 91,2% de TKA) (p>0,999). Conclusão: Pacientes submetidos a UKA ou TKA apresentaram o mesmo grau de satisfação e taxa de complicações pós-operatórias quando comparados pacientes com osteoartrite medial isolada. Os pacientes da UKA apresentaram resultados menos favoráveis ao questionário clínico funcional do que os pacientes submetidos à artroplastia total. Nível de Evidência III; Estudo Retrospectivo.

2.
Acta ortop. bras ; 31(spe2): e262186, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1439155

ABSTRACT

ABSTRACT Objective Compare the results of medial unicompartmental knee arthroplasty (UKA) using a mobile platform and total knee arthroplasty (TKA) in patients with isolated medial osteoarthritis. Methods Retrospectivecross-sectional study. Preoperative radiographs of 602 patientswho underwent knee arthroplastybetween February 2017 and February 2020 were evaluated. Isolated medial osteoarthritis was found in 125 patients. Of these, 57 underwent UKA and 68 TKA. With chart analysis and telephone interviews, we compared patients' clinical outcomes and degree of satisfaction. The statistical analysis used a confidence level of 5%. Results The group of UKA patients obtained 65.8% of favorable results against 79.1% of those undergoing TKA in the function questionnaire (p<0.0001). The complication rate was statistically similar between the groups(p>0.5). Most patients were satisfied or very satisfied in both groups (88.6% of UKA and 91.2% of TKA) (p>0.999). Conclusion Patients submitted to UKA or TKA have presented the same degree of satisfaction and rate of postoperative complications when comparing patients with isolated medial osteoarthritis. UKA patients had less favorable results onthe clinical functional questionnaire than patients undergoing total arthroplasty. Level Of Evidence III;Retrospective Study.


RESUMO Objetivo Comparar os resultados da artroplastia unicompartimental do joelho (UKA) medial com plataforma móvel e artroplastia total do joelho (TKA) em pacientes com osteoartrose medial isolada. Métodos Estudo transversal retrospectivo. Foram avaliadas radiografias pré-operatórias de 602 pacientes submetidos à artroplastia de joelho entre fevereiro de 2017 e fevereiro de 2020. A osteoartrose medial isolada foi encontrada em 125 pacientes, destes em 57 haviam sido submetidos a UKA e 68 TKA. Com análise de prontuários e entrevistas telefônicas comparamos os resultados clínicos e o grau de satisfação dos pacientes. A análise estatística utilizou nível de confiança de 5%. Resultados O grupo de pacientes com UKA obteve 65,8% de resultados favoráveis contra 79,1% daqueles submetidos à TKA no questionário de função (p<0,0001). A taxa de complicações foi estatisticamente semelhante entre os grupos (p>0,5). A maioria dos pacientes estava satisfeita ou muito satisfeita em ambos os grupos (88,6% de UKA e 91,2% de TKA) (p>0,999). Conclusão Pacientes submetidos a UKA ou TKA apresentaram o mesmo grau de satisfação e taxa de complicações pós-operatórias quando comparados pacientes com osteoartrite medial isolada. Os pacientes da UKA apresentaram resultados menos favoráveis ao questionário clínico funcional do que os pacientes submetidos à artroplastia total. Nível de Evidência III; Estudo Retrospectivo.

3.
Acta Ortop Bras ; 30(1): e253870, 2022.
Article in English | MEDLINE | ID: mdl-35431633

ABSTRACT

Introduction: To compare the functional results, satisfaction rates, and revisions of total knee arthroplasties performed by the same surgical team using either Brazilian or imported implants, with a minimum follow-up of 5 years after surgery. Materials and Methods: A retrospective cohort study analyzing the medical records and interviews of patients who underwent total knee arthroplasty with Brazilian or imported implants with a minimum of 5 years after surgery. Results: One hundred and fifty patients were evaluated (164 knees). In the functional questionnaire, 71% of patients had favorable answers in the group of patients who underwent surgery using the Brazilian prosthesis and 74.8% in the group with imported implants (p=0.634). There was no statistical difference in satisfaction between the groups, with 78.4% of patients satisfied or very satisfied in the Brazilian implant group and 90.7% in the imported implant group (p=0.053). Loosening of the implants was reported in 5.3% versus 4.7% (p>0.999). Conclusion: The total knee arthroplasties performed by the same surgical team with a minimum follow-up period of 5 years showed similar levels of satisfaction, function, and complications with both the Brazilian and imported implants. Level of Evidence III, cohort study.


Introdução: Comparar resultados funcionais, índices de satisfação e revisões de artroplastias totais de joelho realizadas pela mesma equipe cirúrgica usando implantes brasileiros ou importados, com acompanhamento mínimo de cinco anos após a cirurgia. Material e Método: Estudo de coorte retrospectivo com análise de prontuários e entrevistas de pacientes submetidos à artroplastia total do joelho com implantes brasileiros e importados com no mínimo cinco anos de pós-operatório. Resultados: Foram avaliados 150 pacientes (164 joelhos). No questionário funcional, encontramos 71% dos pacientes com respostas favoráveis no grupo de pacientes submetidos à cirurgia com uso de próteses brasileiras e 74,8% no grupo com implantes importados (p = 0,634). Em relação à satisfação, não houve diferença estatística entre os grupos com 78,4% dos pacientes satisfeitos ou muito satisfeitos no grupo com implante brasileiro e 90,7% no grupo com implante importado (p = 0,053). A ocorrência de soltura dos implantes foi relatada em 5,3% versus 4,7% (p > 0,999). Conclusões: As artroplastias totais de joelho realizadas pela mesma equipe cirúrgica com acompanhamento mínimo de cinco anos apresentaram níveis semelhantes de satisfação, função e complicações com os implantes brasileiros e importados. Nível de evidência III, estudo de coorte.

4.
Acta ortop. bras ; 30(1): e253870, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1355582

ABSTRACT

ABSTRACT Introduction To compare the functional results, satisfaction rates, and revisions of total knee arthroplasties performed by the same surgical team using either Brazilian or imported implants, with a minimum follow-up of 5 years after surgery. Materials and Methods A retrospective cohort study analyzing the medical records and interviews of patients who underwent total knee arthroplasty with Brazilian or imported implants with a minimum of 5 years after surgery. Results One hundred and fifty patients were evaluated (164 knees). In the functional questionnaire, 71% of patients had favorable answers in the group of patients who underwent surgery using the Brazilian prosthesis and 74.8% in the group with imported implants (p=0.634). There was no statistical difference in satisfaction between the groups, with 78.4% of patients satisfied or very satisfied in the Brazilian implant group and 90.7% in the imported implant group (p=0.053). Loosening of the implants was reported in 5.3% versus 4.7% (p>0.999). Conclusion The total knee arthroplasties performed by the same surgical team with a minimum follow-up period of 5 years showed similar levels of satisfaction, function, and complications with both the Brazilian and imported implants. Level of Evidence III, cohort study.


RESUMO Introdução Comparar resultados funcionais, índices de satisfação e revisões de artroplastias totais de joelho realizadas pela mesma equipe cirúrgica usando implantes brasileiros ou importados, com acompanhamento mínimo de cinco anos após a cirurgia. Material e Método Estudo de coorte retrospectivo com análise de prontuários e entrevistas de pacientes submetidos à artroplastia total do joelho com implantes brasileiros e importados com no mínimo cinco anos de pós-operatório. Resultados Foram avaliados 150 pacientes (164 joelhos). No questionário funcional, encontramos 71% dos pacientes com respostas favoráveis no grupo de pacientes submetidos à cirurgia com uso de próteses brasileiras e 74,8% no grupo com implantes importados (p = 0,634). Em relação à satisfação, não houve diferença estatística entre os grupos com 78,4% dos pacientes satisfeitos ou muito satisfeitos no grupo com implante brasileiro e 90,7% no grupo com implante importado (p = 0,053). A ocorrência de soltura dos implantes foi relatada em 5,3% versus 4,7% (p > 0,999). Conclusões As artroplastias totais de joelho realizadas pela mesma equipe cirúrgica com acompanhamento mínimo de cinco anos apresentaram níveis semelhantes de satisfação, função e complicações com os implantes brasileiros e importados. Nível de evidência III, estudo de coorte.

5.
Acta Ortop Bras ; 29(6): 312-315, 2021.
Article in English | MEDLINE | ID: mdl-34849096

ABSTRACT

OBJECTIVE: To examine and compare the clinical efficacy of intraarticular epsilon aminocaproic acid (EACA) and tranexamic acid (TXA) in total knee arthroplasty (TKA). METHODS: This study was a prospective, single-center, double-blinded randomized controlled trial, including sixty patients with osteoarthritis of the knee divided into two groups of 30 patients. In the TXA group, 1 g of TXA (0.05 g/ml) was applied intraarticularly, and in the EACA group, 4 g of EACA (0.2 g/ml) was applied intraarticularly. Serum hemoglobin (Hgb) and hematocrit (Htb) were measured during the preoperatively and 24 and 48 hours postoperatively. The range of motion and pain were evaluated by clinical examination. To evaluate knee function before and 2 months after surgery, the Western Ontario and McMaster Universities Index (WOMAC) questionnaire was used. RESULTS: In total, 56 (93.3%) patients were evaluated up to the second postoperative month. No significant difference between the groups (p > 0.05) was found in the decrease in Hgb or Htb at 24 or 48 hours. Regarding assessment of the pain, WOMAC score and gain in knee flexion, no significant advantages up to 60 days after surgery (p > 0.05) were found. CONCLUSIONS: The decrease in Hgb and Htb during the first 48 hours postoperatively and the risk of transfusion were similar with the intraarticular use of 1 g of TXA and 4 g of EACA in TKA. The possible benefits regarding knee pain, gain in flexion and function were also similar for the two drugs. Level of Evidence II, Randomized, Double-Blinded, Single-Centre, Prospective Clinical Trial.


OBJETIVO: Avaliar e comparar a eficácia clinica do uso intra-articular do ácido épsilon aminocaproico (AEAC) versus o ácido tranexâmico (ATX) na prótese total do joelho. MÉTODOS: Estudo clínico prospectivo, centro-único, duplo-cego e randomizado. Sessenta pacientes com osteoartrose de joelho foram incluídos. Os participantes foram divididos em dois grupos de 30 pacientes. No grupo ATX, foi aplicado 1 g de ATX (0.05 g/ml) intra-articular e, no grupo AEAC, foram aplicados 4 g de AEAC (0.2 g/ml) intra-articular. Valores séricos da hemoglobina (Hb) e hemtatócrito (Ht) foram dosados no pré-operatório e com 24 e 48 horas após a cirurgia. A amplitude de movimento e a dor também foram avaliadas no exame clínico. O índice WOMAC foi utilizado para avaliar a função do joelho antes e após dois meses da cirurgia. RESULTADOS: Foram avaliados 56 (93.3%) pacientes até o segundo mês pós-operatório. Depois da cirurgia, não houve diferenças entre os grupos (p > 0.05) na queda do valor de Hb e Ht com 24 ou 48 horas. Com relação à avaliação da dor, WOMAC e ganho de flexão do joelho, não houve vantagem significativa para nenhum dos grupos até os 60 dias depois da cirurgia(p > 0.05). CONCLUSÃO: A queda do valor da Hb e do Ht durante as primeiras 48 horas pós-operatórias e o risco de transfusão foram similares com o uso intra-articular de 1 g de ATX e 4 g de AEAC na artroplastia total do joelho. Os possíveis benefícios com relação ao controle da dor, ganho de flexão e função foram similares entre as duas drogas. Nível de Evidência II, Ensaio-Clínico Prospectivo, Randomizado, Duplo Cego, Centro-Único.

6.
Acta ortop. bras ; 29(6): 312-315, Nov.-Dec. 2021. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1349905

ABSTRACT

ABSTRACT Objective: To examine and compare the clinical efficacy of intraarticular epsilon aminocaproic acid (EACA) and tranexamic acid (TXA) in total knee arthroplasty (TKA). Methods: This study was a prospective, single-center, double-blinded randomized controlled trial, including sixty patients with osteoarthritis of the knee divided into two groups of 30 patients. In the TXA group, 1 g of TXA (0.05 g/ml) was applied intraarticularly, and in the EACA group, 4 g of EACA (0.2 g/ml) was applied intraarticularly. Serum hemoglobin (Hgb) and hematocrit (Htb) were measured during the preoperatively and 24 and 48 hours postoperatively. The range of motion and pain were evaluated by clinical examination. To evaluate knee function before and 2 months after surgery, the Western Ontario and McMaster Universities Index (WOMAC) questionnaire was used. Results: In total, 56 (93.3%) patients were evaluated up to the second postoperative month. No significant difference between the groups (p > 0.05) was found in the decrease in Hgb or Htb at 24 or 48 hours. Regarding assessment of the pain, WOMAC score and gain in knee flexion, no significant advantages up to 60 days after surgery (p > 0.05) were found. Conclusions: The decrease in Hgb and Htb during the first 48 hours postoperatively and the risk of transfusion were similar with the intraarticular use of 1 g of TXA and 4 g of EACA in TKA. The possible benefits regarding knee pain, gain in flexion and function were also similar for the two drugs. Level of Evidence II, Randomized, Double-Blinded, Single-Centre, Prospective Clinical Trial.


RESUMO Objetivo: Avaliar e comparar a eficácia clinica do uso intra-articular do ácido épsilon aminocaproico (AEAC) versus o ácido tranexâmico (ATX) na prótese total do joelho. Métodos: Estudo clínico prospectivo, centro-único, duplo-cego e randomizado. Sessenta pacientes com osteoartrose de joelho foram incluídos. Os participantes foram divididos em dois grupos de 30 pacientes. No grupo ATX, foi aplicado 1 g de ATX (0.05 g/ml) intra-articular e, no grupo AEAC, foram aplicados 4 g de AEAC (0.2 g/ml) intra-articular. Valores séricos da hemoglobina (Hb) e hemtatócrito (Ht) foram dosados no pré-operatório e com 24 e 48 horas após a cirurgia. A amplitude de movimento e a dor também foram avaliadas no exame clínico. O índice WOMAC foi utilizado para avaliar a função do joelho antes e após dois meses da cirurgia. Resultados: Foram avaliados 56 (93.3%) pacientes até o segundo mês pós-operatório. Depois da cirurgia, não houve diferenças entre os grupos (p > 0.05) na queda do valor de Hb e Ht com 24 ou 48 horas. Com relação à avaliação da dor, WOMAC e ganho de flexão do joelho, não houve vantagem significativa para nenhum dos grupos até os 60 dias depois da cirurgia(p > 0.05). Conclusão: A queda do valor da Hb e do Ht durante as primeiras 48 horas pós-operatórias e o risco de transfusão foram similares com o uso intra-articular de 1 g de ATX e 4 g de AEAC na artroplastia total do joelho. Os possíveis benefícios com relação ao controle da dor, ganho de flexão e função foram similares entre as duas drogas. Nível de Evidência II, Ensaio-Clínico Prospectivo, Randomizado, Duplo Cego, Centro-Único.

7.
J Surg Case Rep ; 2021(6): rjab242, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34158914

ABSTRACT

Spontaneous osteonecrosis or subchondral bone insufficiency fracture of the knee is a frequent injury in elderly female patients. The medial femoral condyle followed by the medial plateau is the most prevalent sites. When its evolution after conservative treatment is not favorable, medial unicompartimental arthroplasty is a surgical option with good results. We report three cases of early tibial component loosening of medial unicompartimental arthroplasty that could be related to a severe subchondral bone insufficiency fracture of the tibial plateau. In these cases of severe involvement of the tibial plateau, a more careful evaluation would be recommended to choose between unicompartimental and total knee replacement to avoid this early loosening.

8.
Int Orthop ; 45(2): 463-471, 2021 02.
Article in English | MEDLINE | ID: mdl-32990794

ABSTRACT

PURPOSE: Evaluate the effects of intra-operative leucocyte-poor-platelet-rich plasma (PRP) (type P3-Bß with endogenous activation) injection in International Cartilage Repair Society (ICRS) grade III knee chondral injuries treated by chondroplasties, to increase and ameliorate the repair tissue. METHODS: Patients were divided into two groups. Group A (control) consisted of 31 patients and Group B (PRP) 33 patients, totaling 64 patients analyzed. Patients also could had associated injuries (meniscal and/or ACL) being equally divided between both groups to avoid bias. PRP was injected at the end of surgery in group B. The patient outcomes were assessed using subjective International Knee Documentation Committee (IKDC) form, Knee Injury and Osteoarthritis Outcome Score (KOOS), and Tegner activity forms, prior to the surgery and three, six, 12, and 24 months after surgery (medium-term follow up). RESULTS: IKDC and KOOS scores showed increase at each evaluation time points after surgery in both groups, but the treated Group (B) showed a higher increase with statistically significant difference. The Tegner activity scores were higher for the treated group only at six and 12 months. CONCLUSION: Based on the subjective IKDC, KOOS, and Tegner scores, those patients affected by ICRS grade III chondral injuries undergoing arthroscopic chondroplasty who were also treated with PRP showed better and faster outcomes than the control group. Independently from the associated injury (meniscal or ACL). This difference could be measured for up to two years.


Subject(s)
Knee Injuries , Platelet-Rich Plasma , Humans , Knee Injuries/surgery , Knee Joint/surgery , Lysholm Knee Score , Prospective Studies , Treatment Outcome
9.
Acta Ortop Bras ; 27(5): 248-251, 2019.
Article in English | MEDLINE | ID: mdl-31839732

ABSTRACT

OBJECTIVE: To evaluate the efficacy of platelet-rich plasma (PRP) and tranexamic acid (TXA) applied in total knee arthroplasty. METHODS: We selected and randomized 84 patients. TXA was applied in 23 patients, PRP in 20, and PRP in combination with TXA in 20. Hemoglobin was measured preoperatively and 24 and 48 hours postoperatively. The function questionnaire, pain scale and gain of knee flexion were monitored until the second postoperative year. RESULTS: There was a difference (p <0.01) in the decrease in hemoglobin 48 hours after surgery between the TXA group and the control and PRP groups. In terms of pain, the TXA group at 24 and 48 hours after surgery and the PRP group at 48 hours after surgery showed advantages (p <0.01). Knee flexion gain in the first 24 hours postoperatively was better in the TXA group (p <0.05). CONCLUSION: TXA was effective in lowering the drop in hemoglobin level, reducing pain and improving movement gain 48 hours after the procedure. PRP was not effective in reducing bleeding or improving knee function after arthroplasty, but provided better control of postoperative pain. Level of Evidence I, Randomized, blinded, prospective clinical trial.


OBJETIVO: Avaliar a eficácia do plasma rico em plaquetas (PRP) e do ácido tranexâmico (ATX) aplicados na artroplastia total do joelho. MÉTODOS: Selecionamos e randomizamos 84 pacientes. ATX foi aplicado em 23 pacientes, PRP em 20, e PRP associado a ATX em 20. A hemoglobina foi medida no pré-operatório e nas 24 e 48 horas após a cirurgia. O questionário de função, a escala de dor e o ganho de flexão do joelho foram verificados até o segundo ano de pós-operatório. RESULTADOS: Houve diferença(p < 0,01) na diminuição da hemoglobina 48 horas após a cirurgia entre o grupo ATX e os grupos controle e PRP. Na dor, o grupo ATX 24 e 48 horas após a cirurgia e o grupo PRP 48 horas após a cirurgia apresentaram vantagens (p < 0,01). O ganho de flexão do joelho nas primeiras 24 horas de pós-operatório foi melhor no grupo ATX (p < 0,05). CONCLUSÃO: O ATX foi eficaz na diminuição da queda da hemoglobina, reduzindo a dor e melhorando o ganho de movimento em 48 horas após o procedimento. O PRP não foi eficaz na redução do sangramento ou na melhora da função do joelho após a artroplastia, mas proporcionou melhor controle da dor pós-operatória. Nível de Evidência I, Randomizado, duplo cego, ensaio clínico prospectivo.

10.
Acta ortop. bras ; 27(5): 248-251, Sept.-Oct. 2019. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1038172

ABSTRACT

ABSTRACT Objective: To evaluate the efficacy of platelet-rich plasma (PRP) and tranexamic acid (TXA) applied in total knee arthroplasty. Methods: We selected and randomized 84 patients. TXA was applied in 23 patients, PRP in 20, and PRP in combination with TXA in 20. Hemoglobin was measured preoperatively and 24 and 48 hours postoperatively. The function questionnaire, pain scale and gain of knee flexion were monitored until the second postoperative year. Results: There was a difference (p <0.01) in the decrease in hemoglobin 48 hours after surgery between the TXA group and the control and PRP groups. In terms of pain, the TXA group at 24 and 48 hours after surgery and the PRP group at 48 hours after surgery showed advantages (p <0.01). Knee flexion gain in the first 24 hours postoperatively was better in the TXA group (p <0.05). Conclusion: TXA was effective in lowering the drop in hemoglobin level, reducing pain and improving movement gain 48 hours after the procedure. PRP was not effective in reducing bleeding or improving knee function after arthroplasty, but provided better control of postoperative pain. Level of Evidence I, Randomized, blinded, prospective clinical trial.


RESUMO Objetivo: Avaliar a eficácia do plasma rico em plaquetas (PRP) e do ácido tranexâmico (ATX) aplicados na artroplastia total do joelho. Métodos: Selecionamos e randomizamos 84 pacientes. ATX foi aplicado em 23 pacientes, PRP em 20, e PRP associado a ATX em 20. A hemoglobina foi medida no pré-operatório e nas 24 e 48 horas após a cirurgia. O questionário de função, a escala de dor e o ganho de flexão do joelho foram verificados até o segundo ano de pós-operatório. Resultados: Houve diferença(p < 0,01) na diminuição da hemoglobina 48 horas após a cirurgia entre o grupo ATX e os grupos controle e PRP. Na dor, o grupo ATX 24 e 48 horas após a cirurgia e o grupo PRP 48 horas após a cirurgia apresentaram vantagens (p < 0,01). O ganho de flexão do joelho nas primeiras 24 horas de pós-operatório foi melhor no grupo ATX (p < 0,05). Conclusão: O ATX foi eficaz na diminuição da queda da hemoglobina, reduzindo a dor e melhorando o ganho de movimento em 48 horas após o procedimento. O PRP não foi eficaz na redução do sangramento ou na melhora da função do joelho após a artroplastia, mas proporcionou melhor controle da dor pós-operatória. Nível de Evidência I, Randomizado, duplo cego, ensaio clínico prospectivo.

11.
Acta Ortop Bras ; 26(2): 94-97, 2018.
Article in English | MEDLINE | ID: mdl-29983624

ABSTRACT

PURPOSE: To present a technical variation in tibial fixation of quadruple hamstring grafts during anatomic reconstruction of the anterior cruciate ligament (ACL). The secondary purpose was to decrease the costs associated with this procedure. METHODS: Twenty patients who underwent ACL reconstruction were selected. A tibial tunnel was constructed using standard techniques, and a femoral tunnel was anatomically created using the outside-in technique. The hamstring autograft was passed (with its bend) into the tibial tunnel and affixed to the tibia using the suspensory technique and a simple staple. Femoral fixation was performed using a titanium interference screw. The patients underwent postoperative evaluations at 0, 3, 6 and 12 months using the subjective International Knee Documentation Committee (IKDC) form and Lysholm knee scores. RESULTS: The IKDC and Lysholm score results improved over time (p<0.001) without major complications. The cost of the procedure could be reduced by using lower-cost hardware (staples). CONCLUSION: The proposed technique for anatomic ACL reconstruction using inverted hamstring grafts with their bend in the tibial tunnel, suspension-type fixation using a staple demonstrated good to excellent results after 1 year of follow up, with lower aggregate costs. Level of Evidence IV; Case series.


OBJETIVO: Apresentar uma variação técnica na fixação do enxerto quádruplo de tendões flexores à tíbia na reconstrução anatômica do ligamento cruzado anterior (LCA). O objetivo secundário é diminuir o custo associado ao procedimento. MÉTODOS: Foram selecionados 20 pacientes que seriam submetidos à reconstrução do LCA. O túnel tibial foi realizado usando técnica padrão, e o túnel femoral foi realizado pela técnica anatômica de fora para dentro. O enxerto (tendões flexores autólogos) foi passado com sua dobra dentro do túnel tibial e fixado com um agrafe simples pela técnica de suspensão. A fixação femoral foi realizada com parafuso de interferência de titânio. Os pacientes foram avaliados no pré-operatório e aos 3, 6 e 12 meses pós-operatórios usando o questionário International Knee Documentation Committee (IKDC) subjetivo e o questionário de Lysholm. RESULTADOS: Os resultados dos escores dos questionários IKDC e Lysholm tiveram sempre melhora com o tempo (p < 0,001) sem maiores complicações. O custo total da cirurgia foi reduzido usando material de custo menor (agrafe). CONCLUSÃO: A técnica proposta para reconstrução anatômica do LCA com enxerto de tendões flexores invertido com sua dobra no túnel tibial, com fixação tipo suspensão com um agrafe, mostrou bons a excelentes resultados após 1 ano de acompanhamento, com menor custo agregado. Nível de Evidência IV; Série de casos.

12.
Acta ortop. bras ; 26(2): 94-97, Mar.-Apr. 2018. tab, graf
Article in English | LILACS | ID: biblio-949733

ABSTRACT

ABSTRACT Purpose: To present a technical variation in tibial fixation of quadruple hamstring grafts during anatomic reconstruction of the anterior cruciate ligament (ACL). The secondary purpose was to decrease the costs associated with this procedure. Methods: Twenty patients who underwent ACL reconstruction were selected. A tibial tunnel was constructed using standard techniques, and a femoral tunnel was anatomically created using the outside-in technique. The hamstring autograft was passed (with its bend) into the tibial tunnel and affixed to the tibia using the suspensory technique and a simple staple. Femoral fixation was performed using a titanium interference screw. The patients underwent postoperative evaluations at 0, 3, 6 and 12 months using the subjective International Knee Documentation Committee (IKDC) form and Lysholm knee scores. Results: The IKDC and Lysholm score results improved over time (p<0.001) without major complications. The cost of the procedure could be reduced by using lower-cost hardware (staples). Conclusion: The proposed technique for anatomic ACL reconstruction using inverted hamstring grafts with their bend in the tibial tunnel, suspension-type fixation using a staple demonstrated good to excellent results after 1 year of follow up, with lower aggregate costs. Level of Evidence IV; Case series.


RESUMO Objetivo: Apresentar uma variação técnica na fixação do enxerto quádruplo de tendões flexores à tíbia na reconstrução anatômica do ligamento cruzado anterior (LCA). O objetivo secundário é diminuir o custo associado ao procedimento. Métodos: Foram selecionados 20 pacientes que seriam submetidos à reconstrução do LCA. O túnel tibial foi realizado usando técnica padrão, e o túnel femoral foi realizado pela técnica anatômica de fora para dentro. O enxerto (tendões flexores autólogos) foi passado com sua dobra dentro do túnel tibial e fixado com um agrafe simples pela técnica de suspensão. A fixação femoral foi realizada com parafuso de interferência de titânio. Os pacientes foram avaliados no pré-operatório e aos 3, 6 e 12 meses pós-operatórios usando o questionário International Knee Documentation Committee (IKDC) subjetivo e o questionário de Lysholm. Resultados: Os resultados dos escores dos questionários IKDC e Lysholm tiveram sempre melhora com o tempo (p < 0,001) sem maiores complicações. O custo total da cirurgia foi reduzido usando material de custo menor (agrafe). Conclusão: A técnica proposta para reconstrução anatômica do LCA com enxerto de tendões flexores invertido com sua dobra no túnel tibial, com fixação tipo suspensão com um agrafe, mostrou bons a excelentes resultados após 1 ano de acompanhamento, com menor custo agregado. Nível de Evidência IV; Série de casos.

13.
Open Orthop J ; 11: 1049-1057, 2017.
Article in English | MEDLINE | ID: mdl-28979607

ABSTRACT

BACKGROUND: The use of tranexamic acid (TXA) in total knee arthroplasty (TKA) has shown good results. Bleeding may cause local complications consequently greater pain and reduced function postoperatively. No study has related the use of TXA to these facts. OBJECTIVE: The aim was to evaluate the effects of TXA haemoglobin, Western Ontario and McMaster Universities Index (WOMAC), pain intensity and flexion gain after TKA. METHODS: 43 patients were randomized and then underwent TKA. TXA was applied to 22 of these patients before closure of the joint capsule. Haemoglobin measurements (mg/dL) were taken preoperatively and 24 and 48 hours after surgery. The WOMAC questionnaire and pain visual analogue scale (VAS) were applied, and flexion gain was measured up to the second postoperative month. Statistical analysis compared the results to determine whether there were differences between the groups for each of the evaluated times. RESULTS: There were differences in favour of the drug 48 hours postoperatively for the haemoglobin variable (p = 0.01), in pain evaluation, 24 and 48 hours, postoperatively (p < 0.01) and in flexion gain, 24 hours after surgery (p = 0.03). There were no significant differences between the groups in the haemoglobin evaluation 24 hours postoperatively, in pain assessment 7 days, 21 days and 2 months, postoperatively, in flexion gain 48 hours, 7 days, 21 days and 2 months, postoperatively and in WOMAC after 2 months. CONCLUSION: In addition to reducing bleeding, topical TXA improved pain and increased flexion gain in the first hours after TKA. TRIAL REGISTRATION: RBR-9b4qgq.

14.
Rev Bras Ortop ; 50(2): 186-94, 2015.
Article in English | MEDLINE | ID: mdl-26229915

ABSTRACT

OBJECTIVE: To evaluate the efficacy of platelet-rich plasma regarding healing, pain and hemostasis after total knee arthroplasty, by means of a blinded randomized controlled and blinded clinical study. METHODS: Forty patients who were going to undergo implantation of a total knee prosthesis were selected and randomized. In 20 of these patients, platelet-rich plasma was applied before the joint capsule was closed. The hemoglobin (mg/dL) and hematocrit (%) levels were assayed before the operation and 24 and 48 h afterwards. The Womac questionnaire and a verbal pain scale were applied and knee range of motion measurements were made up to the second postoperative month. The statistical analysis compared the results with the aim of determining whether there were any differences between the groups at each of the evaluation times. RESULTS: The hemoglobin (mg/dL) and hematocrit (%) measurements made before the operation and 24 and 48 h afterwards did not show any significant differences between the groups (p > 0.05). The Womac questionnaire and the range of motion measured before the operation and up to the first two months also did not show any statistical differences between the groups (p > 0.05). The pain evaluation using the verbal scale showed that there was an advantage for the group that received platelet-rich plasma, 24 h, 48 h, one week, three weeks and two months after the operation (p < 0.05). CONCLUSIONS: In the manner in which the platelet-rich plasma was used, it was not shown to be effective for reducing bleeding or improving knee function after arthroplasty, in comparison with the controls. There was an advantage on the postoperative verbal pain scale.


OBJETIVOS: Avaliar, por meio de um estudo clínico, randomizado, controlado e cego, a eficácia do plasma rico em plaquetas na cicatrização, dor e hemostasia após artroplastia total do joelho. MÉTODOS: Foram selecionados 40 pacientes que seriam submetidos a prótese total do joelho e randomizados. Em 20 desses pacientes foi aplicado o plasma rico em plaquetas antes do fechamento da cápsula articular. Foram feitas dosagens de hemoglobina (mg/dL) e hematócrito (%) no pré-operatório, após 24 e 48 horas da cirurgia. Foram aplicados o questionário Womac e a escala verbal da dor e medidas as amplitudes de movimento do joelho até o segundo mês pós-operatório. A análise estatística comparou os resultados a fim de comprovar haver diferença entre os grupos em cada um dos momentos da avaliação. RESULTADOS: Medidas do valor da hemoglobina (mg/dL) e hematócrito (%) feitas no pré-operatório, após 24 e 48 horas da cirurgia, não mostraram diferenças significativas entre os grupos (p > 0,05). O questionário Womac e a amplitude de movimento medida no pré-operatório e até os dois primeiros meses também não mostraram diferenças estatísticas entre os grupos (p > 0,05). A avaliação da dor por meio da escala verbal mostrou vantagem no grupo que usou o plasma rico em plaquetas após 24 e 48 horas, uma e três semanas e dois meses de pós-operatório (p < 0,05). CONCLUSÕES: Da maneira com que foi usado, o plasma rico em plaquetas não se mostrou efetivo para reduzir sangramento ou melhorar a função do joelho após a artroplastia em comparação com os controles. Houve vantagem na escala verbal de dor pós-operatória.

15.
Rev. bras. ortop ; 50(2): 186-194, Mar-Apr/2015. tab, graf
Article in English | LILACS | ID: lil-748353

ABSTRACT

OBJECTIVE: To evaluate the efficacy of platelet-rich plasma regarding healing, pain and hemostasis after total knee arthroplasty, by means of a blinded randomized controlled and blinded clinical study. METHODS: Forty patients who were going to undergo implantation of a total knee prosthesis were selected and randomized. In 20 of these patients, platelet-rich plasma was applied before the joint capsule was closed. The hemoglobin (mg/dL) and hematocrit (%) levels were assayed before the operation and 24 and 48 h afterwards. The Womac questionnaire and a verbal pain scale were applied and knee range of motion measurements were made up to the second postoperative month. The statistical analysis compared the results with the aim of determining whether there were any differences between the groups at each of the evaluation times. RESULTS: The hemoglobin (mg/dL) and hematocrit (%) measurements made before the operation and 24 and 48 h afterwards did not show any significant differences between the groups (p > 0.05). The Womac questionnaire and the range of motion measured before the operation and up to the first two months also did not show any statistical differences between the groups (p > 0.05). The pain evaluation using the verbal scale showed that there was an advantage for the group that received platelet-rich plasma, 24 h, 48 h, one week, three weeks and two months after the operation (p < 0.05). CONCLUSIONS: In the manner in which the platelet-rich plasma was used, it was not shown to be effective for reducing bleeding or improving knee function after arthroplasty, in comparison with the controls. There was an advantage on the postoperative verbal pain scale. .


OBJETIVOS: Avaliar, por meio de um estudo clínico, randomizado, controlado e cego, a eficácia do plasma rico em plaquetas na cicatrização, dor e hemostasia após artroplastia total do joelho. MÉTODOS: Foram selecionados 40 pacientes que seriam submetidos a prótese total do joelho e randomizados. Em 20 desses pacientes foi aplicado o plasma rico em plaquetas antes do fechamento da cápsula articular. Foram feitas dosagens de hemoglobina (mg/dL) e hematócrito (%) no pré-operatório, após 24 e 48 horas da cirurgia. Foram aplicados o questionário Womac e a escala verbal da dor e medidas as amplitudes de movimento do joelho até o segundo mês pós-operatório. A análise estatística comparou os resultados a fim de comprovar haver diferença entre os grupos em cada um dos momentos da avaliação. RESULTADOS: Medidas do valor da hemoglobina (mg/dL) e hematócrito (%) feitas no pré-operatório, após 24 e 48 horas da cirurgia, não mostraram diferenças significativas entre os grupos (p > 0,05). O questionário Womac e a amplitude de movimento medida no pré-operatório e até os dois primeiros meses também não mostraram diferenças estatísticas entre os grupos (p > 0,05). A avaliação da dor por meio da escala verbal mostrou vantagem no grupo que usou o plasma rico em plaquetas após 24 e 48 horas, uma e três semanas e dois meses de pós-operatório (p < 0,05). CONCLUSÕES: Da maneira com que foi usado, o plasma rico em plaquetas não se mostrou efetivo para reduzir sangramento ou melhorar a função do joelho após a artroplastia em comparação com os controles. Houve vantagem na escala verbal de dor pós-operatória. .


Subject(s)
Humans , Male , Female , Middle Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee , Blood Platelets , Blood Transfusion , Hemorrhage , Plasma
SELECTION OF CITATIONS
SEARCH DETAIL
...